orphan: true


Gelecekteki (olası) Pompa Sürücüleri

Burada üretimde olan bazı pompaların listesi ve herhangi bir döngü sistemindeki destek durumu ile AAPS’deki durumu anlatılmaya çalışılacaktır. Bölüm sonunda bir pompanın “Döngü özellikli” olması için gerekli olan bazı bilgiler vardır.

Döngü yapılabilen Pompalar

Kaleido (Homepage)

Loop status: Pump is a Loop candidate, but protocol is unknown at the time. No interest in open source from the vendor.

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:slim X2 (Homepage)

Loop status: Not yet loopable.

While in the past company has decided not to allow their pumps to be controlled by external devices, it seems that last few years have been a game changer. Company decided to upgrade their t:slim X2 pump to be able to be controlled remotely (via t:connect app), which means that avenues are opened that we might be able to look forward to have control of pump via AAPS in the future. New pump firmware is planned to be released soon (this or next year, before their tubeless pump t:sport comes out). There are no details yet, what operations will be possible from t:connect (Bolus definitely, everything else unknown).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:Mobi & t:slim X3 & t:Mobi Tubeless (Homepage)

Loop status: All 3 pumps will be Loop candidates.

Awaiting release in Europe.

Hardware requirement for AAPS: None. It seems to be BT enabled.

Willcare Insulin pump (Homepage)

Loop status: At the moment its not Loop candidate, but we were contacted by their staff and they interested in extending their pump to be loopable (at the moment I think its missing only get/set profile commands).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Comments: Since company is interested in integration with AAPS, they might do implementation themselves.

Pompalar artık satılmıyor (şirketler artık çalışmıyor)

Animas Vibe

Animas Ping

Cellnovo

Accu-Chek Insight

Comments: End of support March 2025.

Döngü yapılamayan pompalar

Medtronic Bluetooth

Comments: Medtronic withdrew.

Accu-Chek Solo

Comments: No community success in communicating with the Solo pump.

Ypsomed Pump

Comments: Ypso added very heavy 3rd party encryption.

Döngü yapılabilecek pompalar için gereksinimler

Prerequisite

  • Pompanın bir çeşit uzaktan kumandayı desteklemesi gerekir. (BT, Radyo frekansı, vb)

  • Saldırıya uğramış/dokümante edilmiş/vb. protokeller.

Minimal requirement

  • Geçici Bazal Oranı Ayarla

  • Durum Al

  • Geçici Bazal Oranı İptal Et

For oref1(SMB) or Bolusing:

  • Bolusu Ayarla

Good to have

  • Bolus iptal Etme

  • Bazal Profili Alma (ne zaman gerekirse)

  • Bazal Profili Ayarlama (olması güzel)

  • Geçmişi Okuma

Other (not required but good to have)

  • Yayma Bolusu Ayarlama

  • Yayma Bolusu iptal etme

  • Geçmişi Okuma

  • GTD’yi okuma

Other pumps support

If you have any other pumps you would like to see status on, please contact us on discord.